![]() ![]() Once the APU boot sequence stops, you will start seeing SOPHOS booting from the USB and the console output will be readable as usual. APU will output the boot sequence on 115200 rate, which means that you will see some garbage output for few seconds. You should configure your putty or screen to run on 38400 baud rate and boot the APU board. This may seem like a problem, but in practice it's not. APU2 and APU3 boards run on 115200 baud rate, Sophos installation process requires 38400 baud rate. Connect through the serial cable on non-standard baud rate Insert your newly created USB into the APU board and connect your serial cable. Make sure you replace sdX with your usb device. ![]() If you are using Linux or Mac, you can use dd, like this: dd if=SW-SFOS_17.0.6_MR-6-181.iso of=/dev/sdX bs=4M sync Go to Sophos website and register to download the "Sophos XG"Īt the end of the registration process you should be able to download the "SW-SFOS_17.0.6_MR-6-181.iso" or similar Create bootable SOPHOS XG USB Sophos XG Firewall Home Edition installation image Boot sophos, connect to WEB interface and finish the installation.Connect through the serial cable on non-standard baud rate.Register at Sophos and download the "Sophos XG Firewall Home Edition" installation.It's actually very easy if you know the steps. Here's the step by step, easy tutorial. It's possible to install SOPHOS XG over the serial connection on APU2 and APU3 boards. SOPHOS XG serial-console installation instruction for APU ![]()